CG Series Clamp-on Ultrasonic Flow Sensors

Our Ultrasonic Flow Sensors

Precision, Reliability, and Customization for Every Application.

CG Series Clamp-on Ultrasonic Flow Sensors / Flow Meters

CG series ultrasonic clamp-on flow sensors / flow meters are compact in size, and can measure flow and output results without external circuitry.
 
The flow sensors/ flow meters can be directly clamped on flexible plastic tubing to accurately measure the liquid flow rate and detect air bubbles. The flow sensor / flow meters are not in direct contact with the liquid in the tubing and will not contaminate the liquid.
 
They are especially suitable for applications where strict hygiene is required, such as biopharmaceutical processes, medical equipment, and battery manufacturing equipment and industrial automation.
cg

Product Features

High Accuracy: ±3%

The flow rate measurement accuracy is essential for applications requiring stringent quality control and process optimization.

Hygienic Safety

The non-invasive measurement reduces the contamination risk and makes it ideal for sensitive applications in the pharmaceutical industries, ensuring safety and compliance with health regulations.

Bi-Directional Flow Measurement

Support accurately calculating fluid volume and detecting air bubbles. Additionally, it can perform volume dosing and function as a flow switch, providing a multifunctional solution that enhances operational versatility.

Compact Design

The embedded circuit eliminates external wiring, streamlining installation and reducing space requirements. This design simplifies setup while maintaining high performance.

No Blockages

Designed to operate without blockage or dead zones, enables smoother fluid flow and reduces potential system strain.

Output

CG series ultrasonic flow sensor/flow meters offers multi-output methods that facilitate seamless integration with existing systems.

Technical Parameter

Measurement
Measures instantaneous flow & cumulative volume, with bidirectional capability
Accuracy
±3% RD(Reading) plus zero point drift *(water, 22°C ±3°C)
Measurable Liquids
Water, saline, blood, beverages, and other acoustically transparent liquids
Applicable Tubing
PVC, PTFE, PE, or other plastic tubing, silicone tubing
Compact Design
Sensor and circuit systems are integrated into one unit
Signal Output
RS485, pulse, current, voltage, and digital output options
Current Consumption
<20mA (no external load)
Operating Voltage
12VDC-30VDC
Liquid Temperature
0°C -60°C
Ambient Temperature
0°C -60°C
Storage Temperature
-20°C -70°C
Work Humidity
10% – 90%RH(no condensation)
Protection Level
IP65

Product Specifications

Product Model Flow Range Outer Diameter Inner Diameter
CG016NS
0-2,000 mL/min
5/32″ 4.0mm
1/16″ 1.6mm
CG019NS
0-2,000 mL/min
3/16″ 4.8mm
1/16″ 1.6mm
CG025NS
0-3,000 mL/min
1/4″ 6.4mm
1/8″ 3.2mm
CG032NS
0-6,000 mL/min
5/16″ 7.9mm
3/16″ 4.8mm
CG038NS
0-8,000 mL/min
3/8″ 9.5mm
1/4″ 6.4mm
CG044NS
0-9,000 mL/min
7/16″ 11.1mm
5/16″ 7.9mm
CG050NS
0-10,000 mL/min
1/2″ 12.7mm
3/8″ 9.5mm
CG056NS
0-12,000 mL/min
9/16″ 14.3mm
3/8″ 9.5mm
CG063NS
0-14,000 mL/min
5/8″ 15.9mm
3/8″ 9.5mm
CG075NS
0-20,000 mL/min
3/4″ 19.1mm
1/2″ 12.7mm
CG100NS
0-50,000 mL/min
1″ 25.4mm
3/4″ 19.1mm
CG125NS
0-100,000 mL/min
1 1/4″ 31.8mm
3/4″ 19.1mm
CG138NS
0-100,000 mL/min
1 3/8″ 35.0mm
7/8″ 22.2mm

Case in Medical

feeb264f0cc917fbf7fcea842e7b4ea4

Kidney Stone Treatment Device

In ureteroscopic holmium laser lithotripsy, continuous water flow infusion is essential, as it serves multiple purposes, including stone fragmentation, cooling, and maintaining clear endoscopic imaging. 

f1a3e062ece4db502fab73562a56f379

VAD Cardiovascular Research

N Medical Company is a well-known manufacturer of VAD in China, focusing on the research and production of medium- and short-term ventricular assist devices (VADs). 